| Elektromagnetisk kompatibilitet | FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A |
| Immunitetsstandard | EN 55024, CISPR 24; IEC 61000-4-2; 4 kV CD, 8 kV AD; IEC 61000-4-3; 3 V/m; IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line); IEC 61000-4-5; 1 kV/2 kV AC; IEC 61000-4-6; 3 V; IEC 61000-4-8; 1 A/m, 50 or 60 Hz; IEC 61000-4-11; >95% reduction, 0.5 period; 30% reduction, 25 periods; EN 61000-3-2, IEC 61000-3-2; EN 61000-3-3, IEC 61000-3-3 |
| Samsvar med industristandarder | EN: EN55024, CISPR 24; ESD: IEC 61000-4-2; 4 kV CD, 8 kV AD; Radiated: IEC 61000-4-3; 3V/m; EFT/Burst: IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line); Surge: IEC 61000-4-5; 1 kV/2 kV AC; Conducted: IEC 61000-4-6; 3V; Power frequency magnetic field: IEC 61000-4-8; 1A/m, 50 or 60 Hz; Voltage dips and interruptions: IEC 61000-4-11; >95% reduction, 0.5 period; 30% reduction, 25 periods; Harmonics: EN61000-3-2, IEC61000-3-2; Flicker: EN61000-3-3, IEC61000-3-3 |
| Sikkerhet | CSA 22.2 No. 60950; UL 60950; IEC 60950; EN 60950 |
| Akustisk trykkemisjon | Power: 55.1 dB, Pressure: 44.8 dB, ISO 7779, ISO 9296 |
| Driftshøyde | up to 4.6 km |
| Luftfuktighetsområde ved drift | 15 to 95% @ 104°F (40°C) (noncondensing) |
| Fuktighet ved lagring | 15 to 90% @ 149°F (65°C) (noncondensing) |
| Driftstemperaturområde | 0 to 55°C |
| Lagringstemperatur | -40 to 70°C |
| Varmespredning | 865 BTU/hr (912.9 kJ/hr) |
| Rutingstabellstørrelse | 10000 entries |
| Svitsjfiberhastighet | 105.6 Gb/s |
| Ruting/svitsjekapasitet | 101.8 Gb/s |
| Størrelse på adressetabell | 64000 entries |
| Administrasjonsfunksjoner | IMC - Intelligent Management Center; command-line interface; Web browser; configuration menu; out-of-band management (serial RS-232C) |
| Kommunikasjon | RFC 783 TFTP; RFC 2925 Ping MIB; RFC 951 BootP; RFC 1542 BootP; RFC 854 Telnet; RFC 768 UDP; RFC 792 ICMP; RFC 793 TCP; RFC 826 ARP; RFC 2030 Simple Network Time Protocol; IEEE 802.3x Flow Control; DHCP Relay; RFC 3046 DHCP Relay Agent Information Option 82; RFC 3376 IGMPv1/v2/v3; RFC 2453 RIPv2; RFC 2328 OSPFv2 (Premium Edge License); IGMPv3; IEEE 802.1D Spanning Tree; IEEE 802.1w Rapid Convergence Spanning Tree; IEEE 802.1s Multiple Spanning Trees; IEEE 802.3ad Link Aggregation Control Protocol; IEEE 802.1AB Link Layer Discovery Protocol; ANSI/TIA-1057 LLDP Media Endpoint Discovery (MED); RFC 2474 DiffServ Precedence; RFC 2597 DiffServ Expedited Forwarding (EF); RFC 2598 DiffServ Assured Forwarding (AF); RFC 1492 TACACS+; RFC 2138 RADIUS; RFC 2866 RADIUS accounting; SSHv2 Secure Shell; Secure Sockets Layer (SSL); IEEE 802.1X Network Login; 802.3af Power over Ethernet; IEEE 802.1Q VLAN tagging; IEEE 802.1Q GVRP; IEEE 802.1p Priority; SNMPv1/v2c/v3; HTML and telnet management; RFC 1493 Bridge MIB; PIM Dense Mode (Premium Edge License); PIM Sparse Mode (Premium Edge License); RFC 1213 MIB II; RFC 2096 IP Forwarding Table MIB; RFC 2737 Entity MIB; RFC 2863 Evolution of Interface; RFC 2665 Ethernet MIB; RFC 3768 VRRP (Premium Edge License); RFC 2787 VRRP MIB; RFC 1058 RIP; RFC 1724 RIPv2 MIB; RFC 2819 Four groups of RMON: 1 (statistics), 2 (history), 3 (alarm) and 9 (events); XRMON; UDLD (Uni-directional Link Detection); RFC 2021 RMON probe configuration (RMON v2); RFC 2668 802.3 MAU MIB; RFC 2613 SMON; RFC 2674 802.1p and IEEE 802.1Q Bridge MIB; RFC 1850 OSPF MIB; RFC 2618 RADIUS Client MIB; RFC 2620 RADIUS Accounting MIB; RFC 3101 OSPF NSSA; RFC 1519 CIDR; RFC 3046 DHCP Relay Agent Information Option; RFC 3176 sFlow |
| BGP | RFC 1997 BGP Communities Attribute; RFC 2918 Route Refresh Capability; RFC 4271 A Border Gateway Protocol 4 (BGP-4); RFC 4456 BGP Route Reflection: An Alternative to Full Mesh Internal BGP (IBGP); RFC 5492 Capabilities Advertisement with BGP-4 |
| Enhetsbehandling | RFC 1591 DNS (client); HTML and telnet management |
| Generelle protokoller | IEEE 802.1ad Q-in-Q; IEEE 802.1AX-2008 Link Aggregation; IEEE 802.1D MAC Bridges; IEEE 802.1p Priority; IEEE 802.1Q VLANs; IEEE 802.1s Multiple Spanning Trees; IEEE 802.1v VLAN classification by Protocol and Port; IEEE 802.1w Rapid Reconfiguration of Spanning Tree; IEEE 802.3ad Link Aggregation Control Protocol (LACP); IEEE 802.3af Power over Ethernet; IEEE 802.3x Flow Control; RFC 768 UDP; RFC 783 TFTP Protocol (revision 2); RFC 792 ICMP; RFC 793 TCP; RFC 826 ARP; RFC 854 TELNET; RFC 868 Time Protocol; RFC 951 BOOTP; RFC 1058 RIPv1; RFC 1350 TFTP Protocol (revision 2); RFC 1519 CIDR; RFC 1542 BOOTP Extensions; RFC 2030 Simple Network Time Protocol (SNTP) v4; RFC 2131 DHCP; RFC 2453 RIPv2; RFC 2548 (MS-RAS-Vendor only); RFC 3046 DHCP Relay Agent Information Option; RFC 3576 Ext to RADIUS (CoA only); RFC 3768 VRRP; RFC 4675 RADIUS VLAN & Priority; UDLD (Uni-directional Link Detection) |
| IP Multicast | RFC 3376 IGMPv3 (host joins only); RFC 3973 PIM Dense Mode; RFC 4601 PIM Sparse Mode |
| IPv6 | RFC 1981 IPv6 Path MTU Discovery; RFC 2375 IPv6 Multicast Address Assignments; RFC 2460 IPv6 Specification; RFC 2464 Transmission of IPv6 over Ethernet Networks; RFC 2710 Multicast Listener Discovery (MLD) for IPv6; RFC 2925 Definitions of Managed Objects for Remote Ping, Traceroute, and Lookup Operations (Ping only); RFC 3019 MLDv1 MIB; RFC 3315 DHCPv6 (client and relay); RFC 3484 Default Address Selection for IPv6 ; RFC 3587 IPv6 Global Unicast Address Format; RFC 3596 DNS Extension for IPv6; RFC 3810 MLDv2 for IPv6; RFC 4022 MIB for TCP; RFC 4087 IP Tunnel MIB; RFC 4113 MIB for UDP; RFC 4213 Basic Transition Mechanisms for IPv6 Hosts and Routers ; RFC 4251 SSHv6 Architecture; RFC 4252 SSHv6 Authentication; RFC 4253 SSHv6 Transport Layer; RFC 4254 SSHv6 Connection; RFC 4291 IP Version 6 Addressing Architecture ; RFC 4293 MIB for IP; RFC 4294 IPv6 Node Requirements; RFC 4419 Key Exchange for SSH; RFC 4443 ICMPv6; RFC 4541 IGMP & MLD Snooping Switch; RFC 4861 IPv6 Neighbor Discovery; RFC 4862 IPv6 Stateless Address Auto-configuration; RFC 5095 Deprecation of Type 0 Routing Headers in IPv6 ; RFC 5340 OSPFv3 for IPv6; RFC 5453 Reserved IPv6 Interface Identifiers; RFC 5519 Multicast Group Membership Discovery MIB (MLDv2 only) ; RFC 5722 Handling of Overlapping IPv6 Fragments |
| MIBer | IEEE 802.1ap (MSTP and STP MIB's only); RFC 1213 MIB II; RFC 1493 Bridge MIB; RFC 1724 RIPv2 MIB; RFC 1850 OSPFv2 MIB; RFC 2021 RMONv2 MIB; RFC 2096 IP Forwarding Table MIB; RFC 2613 SMON MIB; RFC 2618 RADIUS Client MIB; RFC 2620 RADIUS Accounting MIB; RFC 2665 Ethernet-Like-MIB; RFC 2668 802.3 MAU MIB; RFC 2674 802.1p and IEEE 802.1Q Bridge MIB; RFC 2737 Entity MIB (Version 2); RFC 2787 VRRP MIB; RFC 2863 The Interfaces Group MIB; RFC 2925 Ping MIB; RFC 2933 IGMP MIB |
| Nettverksadministrasjon | IEEE 802.1AB Link Layer Discovery Protocol (LLDP); RFC 2819 Four groups of RMON: 1 (statistics), 2 (history), 3 (alarm) and 9 (events); RFC 3176 sFlow; ANSI/TIA-1057 LLDP Media Endpoint Discovery (LLDP-MED); SNMPv1/v2c/v3; XRMON |
| OSPF | RFC 2328 OSPFv2; RFC 3101 OSPF NSSA; RFC 5340 OSPFv3 for IPv6 |
| QoS/Cos | RFC 2474 DiffServ Precedence, including 8 queues/port; RFC 2597 DiffServ Assured Forwarding (AF); RFC 2598 DiffServ Expedited Forwarding (EF) |
| Sikkerhet | IEEE 802.1X Port Based Network Access Control; RFC 1492 TACACS+; RFC 2865 RADIUS (client only); RFC 2866 RADIUS Accounting; RFC 3579 RADIUS Support For Extensible Authentication Protocol (EAP); Secure Sockets Layer (SSL); SSHv2 Secure Shell |
| Latens | 1000 Mb Latency: < 3.4 µs; 10 Gb/s Latency: < 2.1 µs |
| Gjennomløp | 75.7 million pps |
| Porter | 1 open module slot; 20 autosensing 10/100/1000 ports (IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T);Media Type: Auto-MDIX;Duplex: 10BASE-T/100BASE-TX: half or full; 1000BASE-T: full only; 4 dual-personality ports;each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) with PoE or an open mini-GBIC slot (for use with mini-GBIC transceivers); Supports a maximum of 4 10GbE ports, with optional module; Included |
| Bilde, juridisk ansvarsfraskrivelse | Product image may differ from actual product |
| Webadresse for tilleggsinformasjon | http://www.hp.com/go/procurve/ |
| Minimumsmål (B x D x H) | 44.3 x 39.2 x 4.4 cm |
| Vekt | 6.4 kg |
| Garanti | Limited Lifetime warranty: Advance hardware replacement with next-business-day delivery (available in most countries). See www.hp.com/networking/warrantysummary for duration details. |
| Minne og prosessor | 10G module : ARM9 @ 200 MHz, packet buffer size: 36 Mb QDR SDRAM; Management module : Stackable memory and processor: Freescale PowerPC 8540 @ 666 MHz, 4 MB flash, 128 MB compact flash, 256 MB DDR SDRAM |
| Strømtilgjengelighet | 10.0/5.0 A |
| Strøm | The switch automatically adjusts to any voltage between 100-127 and 200-240 V with either 50 or 60 Hz. |
| Strømforbruk | 623 W (maximum) |
| Strømforbruk (ventemodus) | 98 W |
| Nettfrekvens | 50/60 Hz |
| Driftsstrøm inn | 10.0/5.0 A |
| Strøm | 100-127 VAC/200-240 VAC; 50/60 Hz |
| Nettspenning | 100 - 127 / 200 - 240 VAC |
| PoE-strømforsyning | 398 W PoE+, maximum, depending on model and configuration |
| Montering | Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only |
| Rack-montering | Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only |
| Formfaktor | 1U height |